Technical parameter · Transmission speed
10/100Mbps, full duplex
Product category illustration
I/O & data connectors
Technical parameter · Transmission speed: 10/100Mbps, full duplex · Technical parameter · Internal system electrical terminal rated voltage input: 24V DC (20.4V DC~28.8V DC)
DF50-C-MD-TCP. Remote I/O module. Transmission speed: 10/100Mbps, full duplex; Internal system electrical terminal rated voltage input: 24V DC (20.4V DC~28.8V DC); Internal system electrical terminal rated current input: 0.75A (typical value at 24V).
Use the complete DF50-C-MD-TCP ordering code and review the interface, installation and rating conditions below.
Discuss this product requirement10/100Mbps, full duplex
24V DC (20.4V DC~28.8V DC)
0.75A (typical value at 24V)
Diagnostic alarm, process alarm, connector plugging alarm
-25-60 ℃
The image for this configuration is to be confirmed. Request the image matching your connection requirement.
Request the applicable product image| Manufacturer order number | 30050002748 |
|---|
| Wiring parameters · Strip length | 8-10mm |
|---|
| Technical parameter · Transmission speed | 10/100Mbps, full duplex |
|---|---|
| Technical parameter · Minimum cycle time | 1ms |
| Technical parameter · Internal system electrical terminal rated voltage input | 24V DC (20.4V DC~28.8V DC) |
| Technical parameter · Internal system electrical terminal rated current input | 0.75A (typical value at 24V) |
| Technical parameter · Internal system electrical rated voltage output | 5VDC |
| Technical parameter · Internal system electrical rated current output | 2A |
| Technical parameter · Working voltage | 24V DC+20%/-15% |
| Technical parameter · Transmission distance | 100 m |
| Technical parameter · Transmission medium | Category 5 twisted pair cables |
| Environmental requirements · Impact resistance | 15g, in accordance with IEC 60068-2-27 standard |
| Environmental requirements · Corrosion resistance | Complies with IEC 60068-2-42 and IEC 60068-2-43 standards |
| Environmental requirements · Permissible ambient temperature (during operation) | -25-60 ℃ |
|---|---|
| Environmental requirements · Permissible ambient temperature (storage) | -40-85 ℃ |
| Technical parameter · Alarm function | Diagnostic alarm, process alarm, connector plugging alarm |
|---|---|
| Technical parameter · Number of expandable modules | Thirty-two |
| Technical parameter · PDO data | 1024 bytes |
| Technical parameter · Isolation method | Electrical isolation from the site |
| Technical parameter · Bus address setting | PROFINET specification |
| Environmental requirements · Protection type | IP20 |
| Environmental requirements · Pollution level | 2. Comply with IEC 61131-2 standard |
| Environmental requirements · Working altitude | Temperature without derating: 0-2000m |
| Environmental requirements · Relative humidity (non condensing) | 5-95% RH |
| Environmental requirements · Anti vibration | 4g, in accordance with IEC 60068-2-6 standard |
| Environmental requirements · EMC - Immunity | Complies with EN 61000-6-2 standard |
| Environmental requirements · EMC - Radiated interference | Complies with EN 61000-6-3 standard |
| Environmental requirements · Permissible H2S pollutant concentration at 75% relative humidity | 10ppm |
| Environmental requirements · Permissible SO2 pollutant concentration at 75% relative humidity | 25ppm |
| Wiring parameters · Connection technology: input/output | push-in type terminal blocks |
| Wiring parameters · Crimping area of wire | 0.2~1.5mm²/26~16AWG |
After selecting the connection configuration, review its dimensions, pin assignment and installation requirements. Include the required configuration in your request.
Request this product drawingTechnical parameter · Transmission speed: 10/100Mbps, full duplex.
Technical parameter · Internal system electrical terminal rated voltage input: 24V DC (20.4V DC~28.8V DC); Technical parameter · Internal system electrical rated voltage output: 5VDC; Technical parameter · Working voltage: 24V DC+20%/-15%. Keep each value with its stated standard, class and test condition.
Technical parameter · Internal system electrical terminal rated current input: 0.75A (typical value at 24V); Technical parameter · Internal system electrical rated current output: 2A. Keep each value with its stated standard, class and test condition.
Technical parameter · Alarm function: Diagnostic alarm, process alarm, connector plugging alarm.
Share the model or required specification, quantity and delivery target.
lyxconnector.com