Terminal blocks
 Terminal blocks DCKKB2.5-PV
Product appearance · configuration depends on the selected modelEnlarge image

Terminal blocks

Terminal blocks DCKKB2.5-PV

Overview · Connection method: screw connection · Wiring data · Conductor cross section solid AWG: 28~12

Quotation and selection support
Model
DCKKB2.5-PV
Overview · Connection method
screw connection
Wiring data · Conductor cross section solid AWG
28~12
IEC Electrical parameters · Rated current (III / 3)
24A
IEC Electrical parameters · Rated voltage (III / 3)
500V
Request the applicable drawing

Product overview

DCKKB2.5-PV. Terminal blocks. Connection method: screw connection; Conductor cross section solid AWG: 28~12; Rated current (III / 3): 24A.

Use the complete DCKKB2.5-PV ordering code and review the interface, installation and rating conditions below.

Discuss this product requirement

Product features

01

Overview · Connection method

screw connection

02

Wiring data · Conductor cross section solid AWG

28~12

03

IEC Electrical parameters · Rated current (III / 3)

24A

04

IEC Electrical parameters · Rated voltage (III / 3)

500V

05

Overview · Number of rows

2

Product images

 Terminal blocks DCKKB2.5-PV
· DCKKB2.5-PV

Technical specifications

Product identification

Product identification
Manufacturer order number11020000075

Mechanical & connection

Mechanical & connection
Overview · Connection methodscrew connection
Dimension · Width5.1mm
Dimension · End plate width1.5mm
Dimension · Height61.8mm
Dimension · Height · NS 35/7,563mm
Dimension · Height · NS 35/1570.5mm
Dimension · Length76mm
Wiring data · Strip length8~9mm
Wiring data · Tightening torque0.4N.m
Accessories · Slotted screwdriver size (blade thickness x width)0.6×3.5

Electrical & signal

Electrical & signal
IEC Electrical parameters · Rated voltage (III / 3)500V
IEC Electrical parameters · Rated current (III / 3)24A
IEC Electrical parameters · Rated surge voltage6KV
UL Electrical parameters · Rated voltage300V
UL Electrical parameters · Rated current20A
Electrical performance test · Voltage drop≤3.2mV

Wire & cable

Wire & cable
Wiring data · Conductor cross section solid AWG28~12
Wiring data · Conductor cross section solid0.2~4mm²
Wiring data · Conductor cross section flexible0.2~2.5mm²
Wiring data · Conductor cross section flexible (ferrule without plastic sleeve)0.2-2.5mm²
Wiring data · Conductor cross section flexible (ferrule with plastic sleeve)0.5-1.5mm²

Materials & finish

Materials & finish
Overview · Insulation materialsPA
Overview · Insulating material groupI

Environmental conditions

Environmental conditions
Environmental conditions · Ambient temperature (operation)-40 °C ~ 105 °C(depending on derating curve)
Environmental conditions · Ambient temperature (storage/transportation)-25℃~60℃
Electrical performance test · Temperature rise test≤45 K

Other specifications

Other specifications
Overview · Number of rows2
Overview · Number of connections4
Overview · Open-end side panelsYes
Overview · Flammability rating according to UL94V0
Overview · Standard testIEC60947-7-1
Wiring data · 2 flexible conductors with a TWIN ferrule0.5-1mm²
Wiring data · Screw typeSlotted screw
Wiring data · Screw threadM2.5
Environmental conditions · Relative humidity (storage/transport)25%~75%
Mechanical tests · Mechanical strengthPassed the test
Mechanical tests · Fixing supportPassed the test
Mechanical tests · Rotational pull testPassed the test
Safety test · Anti-finger touchPassed the test
Environmental protection · RoHSNo excessive harmful substances
Environmental protection · REACh SVHCLead 7439-92-1
Marker · Side markerZB5 / WB5
Accessories · BridgeDFA2.5
Accessories · End coverD-DCKKB2.5
Installation · End clampE-WS N / E-PC-1100A
Installation · Terminal strip marker supportKLM3-20x8 / KLM3-44x8 / DLM2 / DBE-1 / DBE-2
Installation · DIN railNS35/7.5 & NS35/15
Marking & Installation · Marking stripZB5
Marking & Installation · Marker cardsDBE-1
Accessories · End clampE-WS
Accessories · DIN railNS35/7.5-1000-00A(H)

Drawings & technical files

DCKKB2.5-PV drawing request

After selecting the connection configuration, review its dimensions, pin assignment and installation requirements. Include the required configuration in your request.

Request this product drawing

Selection questions

What termination arrangement is used?

Overview · Connection method: screw connection. Check installation clearance and mating geometry for this configuration.

What is specified for Wiring data · Conductor cross section solid AWG?

Wiring data · Conductor cross section solid AWG: 28~12.

What current values and conditions apply?

IEC Electrical parameters · Rated current (III / 3): 24A; UL Electrical parameters · Rated current: 20A. Keep each value with its stated standard, class and test condition.

What voltage values and standards apply?

IEC Electrical parameters · Rated voltage (III / 3): 500V; IEC Electrical parameters · Rated surge voltage: 6KV; UL Electrical parameters · Rated voltage: 300V; Electrical performance test · Voltage drop: ≤3.2mV. Keep each value with its stated standard, class and test condition.

Confirm the configuration. Get a quote.

Share the model or required specification, quantity and delivery target.

Enquire about this product

Put a number on your next connection.

Choose a structure, confirm dimensions and enter quantity for a sample budget and negotiation target.

Connection configuration

Purchase requirements

Budget workspace

USD / pc

Confirm a configuration to establish your starting point for negotiation.